Table 26:
Electrical data across power units
Mains connection
Mains frequency
Overvoltage protection
Power supply
Options for generation of supply voltage for the logic
Power input
Properties of primary voltage (to the MF transformer)
Integrated power sup­
ply unit
(Output: X4 between
terminals 5 and 8)
Power system
Logic (X4)
I/O array
Power system
Nominal current logic
Making current logic
Nominal current fan hood
I/O array
Output voltage
Output current
PSI61xx/PSI63xx Lx/Wx: TN,TT,IT
PSI61xx/PSI63xx L1/W1 Pha/GND: max 480VAC
PSI61xx/PSI63xx L2/W2 Pha/GND: max 600VAC (to
be verified)
PSI62xx/PSI64xx/PSI65xx: TN, TT
PSI62xx/PSI64xx/PSI65xx Pha/GND: 300VAC
50 or 60 Hz
Metal oxide varistor (MOV)
Dependent on the integrated power unit.
Typ. 24 V
; 19 ... 30 V
DC
DC
According to I/O module used.
Refer to page 292 et seq.
Via external 24 V
power supply unit or
DC
via own supply through the integrated power supply
unit (is fed internally by mains).
Dependent on the integrated power unit.
approx. 1.5 A
(at 24 V
; without fan hood, without I/O module and
DC
without additional consumers at X5)
approx. 2 A for 10 ms
(at 24 V
; without fan hood, without I/O module and
DC
without additional consumers at X5)
approx. 2 A (at 24 V
)
DC
According to I/O module used.
Refer to page 292 et seq.
1 kHz; pulse-width modulated
24 V
DC
max. 2 A
"
Please note:
When the PSI mains supply is switched on, the spe­
cified output current is only available from mains vol­
tage on, and then only until the PSI mains supply
drops to its lower tolerance limit.
Bosch Rexroth AG
431 / 460
Technical data
to EN 61131-2