Technical data
Table 25:
Environmental data across power units
Degree of protection
Orientation
Temperature range
Cooling
Temperature monitoring
Max. height of the operating location
Climatic category
Air humidity
Corrosion
1)
For required cooling water properties refer to the following documentation:
Operation (in installation
area)
Storage / transport
air-cooled units
water-cooled units
Title
D Rexroth PS6000 Wx / PRC7000
Weld Timer and Welding Trans­
former with watercooling
IP 20; installation area with IP 54 is required
vertically or placed on the back side
+10 ... +55 degrees Centigrade
-25 ... +70 degrees Centigrade
max. 45 degrees Centigrade; forced cooling via tem­
perature-controlled fan hood is required.
For the required properties, refer to
integrated
2000 m above sea level
3K3 according to EN 60721-3-3
Condensation is not permitted.
The ambient air must be free from high levels of
acids, lyes, corrosive materials, salt, metal vapors.