Pack201 | Functional Descriptions | Section 5
5.9 Light Tower
The light tower provides the operator with
a visual indicator of the following machine
conditions:
Amber flashing: Waiting for product or
downstream equipment is in standby�
Red steady: Wrapper normal stopped�
Red flashing: Wrapper emergency
stopped�
Green steady: Wrapper running�
© Bosch Packaging Technology Inc.
All rights reserved 2012
5.10 Pneumatics
The air regulator and gauge regulates and
filters the main air supply to the wrapper�
It is typically set to 60 PSI�