Nokia 9500 MPR User Manual page 380

Microwave packet radio, webeml
Table of Contents

Advertisement

Release 7.0.0 3DB 19286 ACAA Issue 01
Provision cross connections
7. Enter the destination MAC address where the Ethernet flow will be terminated in
Note: The first two digits of the destination MAC address for unprotected ports must be set
to 'unicast' or '00'. The first two digits of the destination MAC address for 1+1 protected and
L1 LAG ports must be set to 'multicast' or '01'. The first two digits of the destination MAC
address for all ERPS ring nodes must be set to 'unicast' or '00'
8. On the ETH-RING pop-up, click >>.
9. Repeat steps
10. On the ETH-RING pop-up, click OK.
11. On the Cross Connection screen, click Apply.
12. From the Connections tab, verify the ETH-RING cross-connections were
To provision a Ring to Ring Cross Connection
1. Double left-click Ring port icon.
380
the MAC Address field.
4
through
on this ERP Instance.
entered correctly.
RING-RING pop-up displays. See
8
to provision additional ETH to Ring cross-connections
Figure
211.