Release 7.0.0 3DB 19286 ACAA Issue 01
WebEML User Manual
2. Configure the parameters that apply to all ports:
3. Click on the Next button. The next screen to open depends on the configuration.
To configure the SDH unit configuration screen (ETSI market only)
1. Perform step
2.
Enter an ID in the One-Shot Tributaries Configuration to provide the ECID
for port #1. The tool will number the other tributaries consecutively from the
number entered.
− TDM Clock Source: Adaptive or Differential.
− Line Length
− Line Coding
− Impedance: select the impedance to be used for the E1 streams
(Unbalanced 75 ohm or Balanced 120 ohm).
− Restoration Criteria: for 1+1 EPS are fixed to "Not Revertive" and cannot be
changed.
− Node Timing: timing from the network element clock as defined in G.8261.
The enabling of the Node Timing is applied to all E1s of the PDH unit. By
enabling the Node Timing the E1 streams in Rx side are retimed at the
output with the network element clock.
2
to configure SDHACC or step
Figure 681
shows the configuration screen for SDHACC.
Select the Port type: SFP-O (Optical) or SFE-E (Electrical)
Use the Provisioning Tool
3
for SDHCHANN.