Siemens SIMATIC NET SCALANCE S615 Configuration Manual page 312

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

Appendix A
A.3 Syslog messages
Severity
Facility
Log text
Standard
Description
Example
Severity
Facility
Log text
Standard
Description
Example
Severity
Facility
Session lock
Log text
Standard
Description
Example
Severity
Facility
Closing a remote access session
Log text
Standard
Description
Example
Severity
Facility
312
Warning
local0
User specific firewall user "{user name}" deactivated by administrator configura‐
tion.
IEC 62443-3-3 Reference: SR 2.1
Access to the user-specific firewall denied. The device administrator has deacti‐
vated the user. (USF user deactivated by admin)
User specific firewall user "usf" deactivated by administrator configuration.
Warning
local0
User specific firewall digital input {trigger pin} deactivated rule set "{firewall rule}".
IEC 62443-3-3 Reference: SR 2.1
Access to the user-specific firewall denied; corresponding rule set was deactiva‐
ted. (USF Digital Input Logout)
User specific firewall digital input 1 deactivated rule set "rs1".
Warning
local0
The session of user {user name} was closed after {time} seconds of inactivity.
IEC 62443-3-3 Reference: SR2.5
The current session was locked due to inactivity.
The session of user admin was closed after 60 seconds of inactivity.
Warning
local0
[JOB] <{connection name}|{config detail}> deleting CHILD_SA after {time second}
seconds of inactivity
IEC 62443-3-3 Reference: SR 2.6
The remote session was ended after a period of inactivity. (IPsec)
[JOB] <to_Baugruppe1|21> deleting CHILD_SA after 20 seconds of inactivity
Info
local0
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents