Configuring with Web Based Management
4.5 "System" menu
Description
With Table 1, you can enable or disable all check boxes of a column of Table 2 at once.
Table 1 has the following columns:
● All Events
Shows that the settings are valid for all events of table 2.
● E-mail / Trap / Log Table / Syslog / Fault / SMS / Digital Out / VPN Tunnel / Cloud
Connector / Firewall
Enable or disable the required type of notification for all events. If "No Change" is selected,
the entries of the corresponding column in table 2 remain unchanged.
● Copy To Table
If you click the button, the setting is adopted for all events of table 2.