Siemens SIMATIC NET SCALANCE S615 Configuration Manual page 139

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

Table 2 has the following columns:
● Event
The "Event" column contains the following:
– Cold/Warm Start
– Link Change
– Authentication Failure
– Fault State Change
– Security Logs
– Firewall Logs
– DDNS Client Logs
– System General Logs
– System Connection Status
– Digital In
– VPN Tunnel
– Secure NTP
– Cloud Connector (only with M804PB)
– Configuration Change
– Service Information
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
The device was turned on or restarted by the user. In the error memory of the device a
new entry is generated with the type of restart performed.
This event occurs only when the port status is monitored and has changed, see "System
> Fault Monitoring > Link Change".
This event occurs when access is attempted with an incorrect password.
The fault status has changed. The fault status can relate to the activated port monitoring,
the response of the digital output or the power supply monitoring.
For an fault to also be signaled by the fault LED "F", you must enable "Fault State
Change" for the "Digital Out". In this case, the fault LED "F" lights up when an internal
error occurs and the digital input is closed.
An entry is made in the security log if the IPsec method was used for VPN.
Each time individual firewall rules are applied, this is recorded in the firewall log. To do
this, the LOG function must be enabled for the various firewall functions.
The event occurs when the DDNS client synchronizes the assigned IP address with the
hostname registered at the DDNS provider.
Connection establishment, change to the configuration.
The connection status has changed.
The event occurs when the status of the digital input has changed.
The event occurs when the status of VPN (IPsec, OpenVPN, SINEMA RC) has changed.
This event occurs when the device receives the system time from a secure NTP server.
This event occurs when the operating state of the Cloud Connector has changed.
This event occurs when the configuration of the device has changed.
For certain events, entries are made in the log table even without configuration. For
these events, you can configure additional subsequent actions here (e-mail, trap,
syslog).
Configuring with Web Based Management
4.5 "System" menu
139

Hide quick links:

Advertisement

Table of Contents
loading