802.1Q VLAN Bridge: Important rules for VLANs
Make sure you keep to the following rules when configuring and operating your VLANs:
● Frames with the VLAN ID "0" are handled as untagged frames but retain their priority value.
● As default, all ports on the device send frames without a VLAN tag to ensure that the end
node can receive these frames.
● You will find the factory assignment of the ports in the section "VLAN (Page 35)".
● The VLANs are in different IP subnets. To allow these to communicate with each other, the
route and firewall rule must be configured on the device.
● If an end node is connected to a port, outgoing frames should be sent without a tag (static
access port). If, however, there is a further switch at this port, the frame should have a tag
added (trunk port).
Procedure
Requirement:
For Base Bridge mode "802.1Q VLAN Bridge" is set
Creating a new VLAN
1. Enter an ID in the "VLAN ID" input box.
2. Click the "Create" button. A new entry is generated in the table. As default, the boxes have
"-" entered.
3. Enter a name for the VLAN under Name.
4. Specify the use of the port in the VLAN. If, for example you select M, the port is a member
of the VLAN. The frame sent in this VLAN is forwarded with the corresponding VLAN tag.
5. Specify the mode of the device.
6. Click the "Set Values" button.