Connecting system interfaces - racks to EM4315
Note
The last bus connector remains open on the last POM4320.
NOTICE
The total length of all connecting cables at the system interface rack / EM4315 must not
exceed 3 m.
SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
6.3 Combined mode with POM4320 - Connecting system interfaces
Connecting
Attach the connecting cable
from the rack to the system
interface
of the EM4315.
Additional POM can be con-
nected with a ribbon cable
to the preceding POM.
The operation of up to 8
additional POM is possible
with an EM4315 expansion
module.