Technical specifications
13.4 Technical specifications of POM
Article number
Input voltage
Design of the power supply
Power
Active power input, max.
Power electronics
Type of load
Type of control of the heating elements
Power capacity, max.
For phase against neutral with fan
•
at 40 °C, max.
For phase against neutral without
•
fan at 40 °C, max.
Switching capacity current per phase,
max.
Short-time withstand current (SCCR)
acc. to UL 508A
Load connection type
Star connection with neutral conductor
(single-phase)
Open delta connection (single-phase)
Closed delta connection (3-phase)
Star connection with neutral conductor
(2-phase)
2-pole switching
Setpoint input
Percent
Watts
214
6BK1942-2AA00-0AA0
Power supply via rack
1 W
Ohmic load
Half-wave control
16.1 kW; At 230 V AC
16.1 kW; At 230 V AC
7.3 kW; At 230 V AC
35 A
50 kA
Yes
No
No
No
No
Yes
No
6BK1942-2CA00-0AA1
Half-wave control, phase
control and soft start
23 kW; At 230 V AC
23 kW; At 230 V AC
50 A
100 kA
SIPLUS HCS4200 PROFINET/PROFIBUS DP