Technical specifications
13.4 Technical specifications of POM
Article number
Connection method
Design of electrical connection for
supply voltage
Connectable conductor cross-
sections, solid
Connectable conductor cross-
sections, finely stranded with
wire end processing
Connectable conductor cross-
sections for AWG cables
Input voltage
Design of the power supply
Power
Active power input, max.
Power electronics
Type of load
Type of control of the heating elements
Power capacity, max.
For phase against phase with fan at
40 °C, max.
For phase against phase without
fan at 40 °C, max.
For phase against neutral with fan
at 40 °C, max.
For phase against neutral without
fan at 40 °C, max.
Switching capacity current per phase,
max.
Short-time withstand current (SCCR)
acc. to UL 508A
Load connection type
Star connection with neutral conductor
(single-phase)
Open delta connection (single-phase)
Closed delta connection (3-phase)
Star connection with neutral conductor
(2-phase)
2-pole switching
220
6BK1942-2DA00-0AA0
Connector, 3-pole with spring-loaded connection
1x (0.75 ... 16 mm²)
1x (0.75 ... 16 mm²)
1x (18 ... 4)
Power supply via rack
1 W
Ohmic load
Half-wave control, phase
control and soft start
40 kW; At 400 V AC
40 kW; At 400 V AC
12.5 kW; At 400 V AC
23 kW; At 230 V AC
7.3 kW; At 230 V AC
50 A
Yes
Yes
No
Yes; Economy circuit
Yes; Phase – neutral con-
ductor, phase – phase
6BK1942-2FA00-0AA0
Half-wave control
23 kW; At 230 V AC
100 kA
No
No
No