Ambient Conditions; Standards; Used Standards - Bosch Rexroth IndraControl VDP 16.1 Project Planning Manual

Operator display
Hide thumbs Also See for Rexroth IndraControl VDP 16.1:
Table of Contents

Advertisement

24/69
Bosch Rexroth AG
Technical Data
4.3

Ambient Conditions

In operation
Max. ambient temper‐
+5 ℃ to +45 ℃
ature
Max. temperature gra‐
Temporal temperature changes
dient
up to 3 K per minute
Relative humidity
Climatic class 3K3 according to
EN 60721,
Non-condensing
Air pressure
Up to 2,000 m above MSL ac‐
cording to DIN 60204
Mechanical strength
Max. vibration:
Frequency range:
10 to 150 Hz
Excursion:
0.075 mm for 10 to 57 Hz
Acceleration:
1 g for 57 to 150 Hz
acc. to EN 60068-2-6
4.4

Standards

4.4.1

Used Standards

EN Standards
Rexroth IndraControl VDP 16.1/40.1/60.1 Operator Display
Transport
-20 ℃ to +60 ℃
Not defined
Climatic class 3K3 according to
EN 60721,
Non-condensing
Not defined
Max. shock:
15 g acc. to DIN IEC 68-2-27,
No breakdown of the function
Fig.4-4:
Ambient conditions
The system components of the Operator display correspond to the following
standards:
Standard
EN 60 204-1
EN 61 000-6-4
EN 61,000-6-2
EN 61 558-2-6
EN 60 664-1
EN 61 131-2
EN 61 131-2
ISO 13 850
EN 60 529
DOK-SUPPL*-VDP16/40/60-PR03-EN-P
Storage
-20 ℃ to +60 ℃
Not defined
Climatic class 3K3 according to
EN 60721,
Non-condensing
Not defined
Max. shock:
15 g acc. to DIN IEC 68-2-27,
No breakdown of the function
Meaning
Electrical equipment of machines
Generic standard, emitted interference (industrial envi‐
ronment)
Generic standard, noise immunity (industrial environ‐
ment)
Transformer for 24 V power supply unit, protective sepa‐
ration
Overvoltage category II
24 V outputs requirements
24 V current supply requirements
Machine safety, emergency stop devices
Degrees of protection (including housings and installation
compartments)