DNC Plant/DNC Cell (FBDN1)
10 Configuration
End-of-line character
The end-of-line character is the character that indicates the end of a line. If the
end-of-line character is converted, the SerIntSvr proceeds as follows:
All end-of-line characters are converted to CR-LF for downloads.
All CR-LF and LF are converted according to the following table for
uploads.

Table 10-7: End-of-line character conversion during download

End-of-line character
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Extract from machine configuration file:
EOBcode=0
Send baud rate
The send baud rate specifies the baud rate (differs from that for the interface
definition ([COM] section)) with which data is transmitted. If 0 is specified for
the baud rate, the baud rate of the interface description ([COM] section) is
used.
Extract from machine configuration file:
SendBaudRate
Send timeout
The send timeout specifies the interval in minutes after which the send job is
aborted if the machine is not ready to receive. The value 0 means that the
system will wait indefinitely.
Extract from machine configuration file:
SendTimeout=1
Send delay
The send delay specifies the interval in seconds by which the send job to the
machine is to be delayed.
Extract from machine configuration file:
SendDelay=0
FBDN1/10-180
Description
No conversion
CR CR
CR LF
LF CR
LF LF
CR CR CR
CR CR LF
CR LF CR
CR LF LF
LF CR CR
LF CR LF
LF LF CR
LF LF LF
CR
RD
=0
Motion Control Information System DNC (FBDN) - 04/10 Edition