05.07
Header size
The header size is specified in bytes. It describes the number of header
characters to be inserted.
Extract from machine configuration file:
HeaderSize=8
Header character
The header character is inserted as an ASCII character in decimal code
(0 ...255) with the factor header size (example: 072 for H).
Extract from machine configuration file:
HeaderChar=72
Note
In this case, the header is HHHHHHHH
Trailer size
The trailer size is specified in bytes. It describes the number of trailer
characters to be inserted.
Extract from machine configuration file:
TrailerSize=6
Trailer character
The trailer character is inserted as an ASCII character in decimal code
(0 ...255) with the factor trailer size (example: 078 for N)
Extract from machine configuration file:
TrailerChar=78
Note
In this case, the trailer is NNNNNN
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
DNC Plant/DNC Cell (FBDN1)
10 Configuration
FBDN1/10-177