Path Action - Siemens Sinumerik 840D sl Programming Manual

Fundamentals
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Path action

12.1 Exact stop (G60, G9, G601, G602, G603)
Note
The commands for activating the exact stop criteria (G601/G602/G603) are only effective if
G60 or G9 is active.
Example
Program code
N5 G602
N10 G0 G60 Z...
N20 X... Z...
...
N50 G1 G601
N80 G64 Z...
...
N100 G0 G9
N110 ...
Further information
G60, G9
G9 generates the exact stop in the current block, G60 in the current block and in all following
blocks.
Continuous-path-mode commands G64 or G641 - G645 are used to deactivate G60.
G601, G602
294
Comment
; Criterion "Exact stop coarse" selected.
; Exact stop modal active.
; G60 continues to act.
; Criterion "Exact stop fine" selected.
; Switchover to continuous-path mode.
; Exact stop acts only in this block.
; Continuous-path mode active again.
Programming Manual, 01/2015, 6FC5398-1BP40-5BA2
Fundamentals

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl

Table of Contents