Measurement Parameters - Siemens SINAMICS S120 System Manual

Hydraulic drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

4.17.5

Measurement parameters

The measurement parameters are displayed in a parameter list.
Figure 4-29
Measurement parameters
The parameters displayed in the list are read from the drive. You can adapt all parameters to
your requirements. Write the changed values to the drive using the enter key.
Further actions
● Use the "Measure >" softkey to open the "Measurement" dialog. You can start a
measurement of the valve characteristic there. After the measurement, the measured
characteristic and the characteristic set in the drive are displayed in a diagram.
● Use the "Back" softkey to return to the "Valve characteristics measurement" dialog.
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
Commissioning
4.17 Editing the valve characteristic
89