Commissioning

4.8 Configuration - connection data

4.8
Configuration - connection data
You can configure the following connection data:
Figure 4-7
● Cylinder mass
Inertial mass of the cylinder in kilograms.
● Cylinder mounting position A side
Mounting position in relation to the A side of the cylinder in degrees.
● Line length A side
Length of the hydraulic line on the A side in millimeters.
● Line length B side
Length of the hydraulic line on the B side in millimeters.
● Internal line diameter
Inner diameter of the hydraulic lines for the A and B sides in millimeters.
You can select from the following options under "Cylinder mounting type":
● At the cylinder barrel
The piston is stationary, the moved mass is attached to the cylinder.
● At the piston rod
The cylinder is fixed, the moved mass is attached to the piston rod.
60
Configuration - connection data
System Manual, 04/2015, 6SL3097-4BA00-0BP1
Hydraulic Drive