Managing Time Synchronization Functions - Siemens RX1500 User Manual

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

Chapter 5
Setup and Configuration
1
Figure 287: SNMP Group Access Configuration Table
1. Add Button
2. Edit Button
3.
Click Delete next to the chosen group.
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 5.12

Managing Time Synchronization Functions

ROX II uses version 4 of the Network Time Protocol (NTP) to synchronize the internal clock with a time source.
NOTE
For more information about version 4 of NTP, refer to
NTP is a fault-tolerant protocol that allows an NTP daemon to automatically select the best of several available
reference clocks to synchronize with. Multiple candidates can be combined to minimize the accumulated error.
The NTP daemon can also detect and avoid reference clocks that are temporarily or permanently advertising the
wrong time.
The NTP daemon achieves synchronization by making small and frequent changes to the internal clock. It
operates in a client-server mode, which allows it to synchronize the internal clock with NTP servers and act as an
NTP server for peer devices.
If multiple NTP servers are available to choose from, the NTP daemon will synchronize with the server that has
the lowest stratum. The stratum is a rating of the server compared to the server with the reference clock. The
reference clock itself appears at stratum 0. A server synchronized with a stratum n server will be running at
stratum n+1.
NTP hosts with a lower stratum are typically configured as NTP servers, while NTP hosts with higher stratums
are configured at the same stratum as their peers. If each NTP server fails, a configured peer will help in
providing the NTP time. It is recommended that at least one server and one peer be configured.
The NTP daemon knows which NTP servers and peers to use in three ways:
• The daemon is configured manually with list of servers to poll