Panasonic AFPE224300 User Manual page 184

Fp-e series panel mounted controller
Hide thumbs Also See for AFPE224300:
Table of Contents

Advertisement

Num-
Name
ber
High speed counter/Pulse output instruction for FP0, FP-e
F166
High-speed
counter
output set
(with channel
specification)
F167
High-speed
counter
output reset
(with channel
specification)
F168
Positioning
control (with
channel
specification)
F169
Pulse output
(with channel
specification)
F170
PWM output
(with channel
specification)
11-86
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Boolean
Operand
HC1S
n, S, Yn
HC1R
n, S, Yn
SPD1
S, n
PLS
S, n
PWM
S, n
Description
Turns output Yn on when the elapsed value of the
built-in high-speed counter reaches the target value
of (S+1, S).
Turns output Yn off when the elapsed value of the
built-in high-speed counter reaches the target value
of (S+1, S).
Outputs a positioning pulse from the specified
output (Y0 or Y1) according to the contents of the
data table beginning at "S".
Outputs a pulse from the specified output (Y0 or
Y1) according to the contents of the data table
beginning at "S".
Performs PWM output from the specified outptu
(Y0 or Y1) according to the contents of the data
table beginning at "S".
Steps