Table 4- 4
Terminal circuit diagrams for emergency stop with 3 digital inputs
Connection to an internal 24 V control volt-
age
Configurable via the service menu
Emergency stop 3 inp."
In 0: Emergency stop device
In 1: Wiring depends on the sensor type and the configuration of Input 1.
4.4.2
Voltage output
Slot X4
DC OUTPUT
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
Connection to an external control voltage
"General setup > Special parameters > FBLOCK configuration > FBLOCK Config.
Function
24 V ±15 %, max. 400 mA / max. 100 mA
Controllers
4.4 Connecting terminals
111