4.4 Connecting terminals

4.4
Connecting terminals
4.4.1

Digital input signals

Slot X6
You can connect certain signals for drive functions at the inputs Input 1, Input 2, Input 3,
Input 4 (X6) and Input 0 (X5). The following table shows how the drive function and input are
assigned depending on the controller.
Table 4- 2
Slot X5/X6
Input 0
Input 1
Input 2
Input 3
Input 4
Input 1, Input 2,
Input 3 and Input 4
inactive
Adjustable via the service menu
1)
FBLOCK config. Standard input"
Adjustable via the service menu
2)
FBLOCK config. Emergency stop 3 inp."
Note
To avoid issuing unintentional door commands, remove the terminals X6 and X5 before
changing the FBLOCK input configuration.
108
Overview of signals for drive functions at slots X5 and X6
ATD401W
Standard input
NDG
(second force and energy
profile)
3)
Parameterizable
(local sensor type)
Partial opening operation
CLOSE DOOR
OPEN DOOR
Deenergize (not a door
command)
"General setup > Special parameters > FBLOCK configuration >
"General setup > Special parameters > FBLOCK configuration >
ATD401W
Emergency stop with 3
1)
inputs
2) 3)
(see Fail-safe digital
control concept)
Stop (inverted)
Parameterizable
(local sensor type)
Partial opening operation
CLOSE DOOR (inverted)
OPEN DOOR (inverted)
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
ATD410W/ATD420W/AT
D430W
INPUT 0: Functions con-
figurable (Page 71) via
free function blocks
(FBLOCK)
INPUT 1: Configurable
as a local sensor type or
via function blocks
(FBLOCK) (Page 71)
Functions configurable
(Page 71) via free func-
tion blocks (FBLOCK)
Deenergize (not a door
command)