Command Descriptions
SENSe:AVERage:TYPE (?)
Group
Related Commands
Syntax
Arguments
Responses
Examples
SENSe:BLOCK[:SIZE] (?)
Group
Related Commands
Syntax
2 50
The SENSe:AVERage:TYPE command sets the average/peak hold mode. The
SENSe:AVERage:TYPE? query returns the current setting of the average/peak hold
mode.
SENSE
SENSe:AVERage:COUNt
SENSe:AVERage:TYPE {OFF|RMS|EXPONENTIAL|PEAK}
SENSe:AVERage:TYPE?
OFF
disables all the average/peak hold functions.
RMS
selects RMS averaging.
EXPONENTIAL
selects averaging with an exponential delay function.
PEAK
selects peak–hold.
{OFF|RMA|EXPONENTIAL|PEAK}
:SENSE:AVERAGE:TYPE RMS
sets the average/peak hold mode to RMS.
The SENSe:BLOCK[:SIZE] command sets the block size of the data that is
acquired in block mode. The SENSe:BLOCK[:SIZE]? query returns the current
block size setting.
SENSE
SENSe:ACQuisition[:MODE]
SENSe:BLOCK[:SIZE] <numeric value>
SENSe:BLOCK[:SIZE]?