Realtime spectrum analyzer
Table of Contents

Advertisement

Examples
CALCulate[1|2]:ACP:BANDwidth(?)
Group
Related Commands
Syntax
Arguments
Responses
Examples
3026 Programmer Manual
CALCULATE[1|2]?
might return CN;69.3579,106.626;;
The CALCulate[1|2]:ACP:BANDwidth command sets the bandwidth used for
ACP measurement. The CALCulate[1|2]:ACP:BANDwidth? query returns the
current bandwidth setting.
CALCULATE
CALCulate[1|2]:ACP:SPACing
CALCulate[1|2]:ACP:BANDwidth <numeric value>
CALCulate[1|2]:ACP:BANDwidth?
Switch "1" specifies the lower window of the data display area, and switch "2"
specifies the upper one.
<numeric value>::=<NR3>
where <NR3> is a bandwidth ranging from 1 Hz to 2E+6 Hz.
<NR3>
:CALCULATE:ACP:BANDWIDTH 3E+5
sets the bandwidth for ACP measurement to 300 kHz.
Command Descriptions
2 17