Configuring
6.8 Parameter view
6.8.2.3

Parameter table

The table below shows the meaning of the individual columns of the parameter table. You
can show or hide the columns as required.
● Column "Offline" = X: Column is visible in offline mode.
● Column "Online" = X: Column is visible in online mode (online connection to the CPU).
Column
Explanation
Name in functional
Name of the parameter in the functional view.
view
The display field is empty for parameters that are not configured via the tech-
nology object.
Name in DB
Name of the parameter in the technology data block.
If the parameter is part of a structure or UDT, the prefix ". ./" is added.
The display field is empty for parameters that are not contained in the technol-
ogy data block.
Full name in DB
Complete path of the parameter in the instance DB.
The display field is empty for parameters that are not contained in the technol-
ogy data block.
Status of configura-
Display of the completeness of the configuration using status symbols.
tion
Compare result
Result of the "Compare values" function.
This column is displayed when there is an online connection.
Start value project
Configured start value in the project.
Error indication if entered values have a syntax or process-related error.
Default value
Value that is pre-assigned to the parameter.
The display field is empty for parameters that are not contained in the technol-
ogy data block.
Start value PLC
Start value in the CPU.
This column is displayed when there is an online connection.
Monitor value
Current value in the CPU.
This column is displayed when there is an online connection.
Modify value
Value that is to be used to change the monitor valuet.
This column is displayed when there is an online connection.
Minimum value
Minimum process-related value of the parameter.
If the minimum value is dependent on other parameters, it is defined:
Maximum value
Maximum process-related value of the parameter.
If the maximum value is dependent on other parameters, it is defined:
Setpoint
Designates the parameter as a setpoint. These parameters can be initialized
online.
162
Offline: By the Start value project.
Online: By the Monitor values.
Offline: By the Start value project.
Online: By the Monitor values.
Offline
X
X
X
X
X
X
X
X
X
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Online
X
X
X
X
X
X
X
X
X
X
X
X