boards.fm
Boards for HiPath 3000
Central Boards
3.2
Central Boards
Caution
7
The system must be powered down and de-energized before removing or inserting
all boards in the HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 and before
removing or inserting the central boards of the HiPath 3800, HiPath 3750 and Hi-
Path 3700.
3.2.1
CBCC
Introduction
The CBCC board (Central Board with Coldfire Com, S30810-Q2935-A301) performs all central
control and switching functions for HiPath 3550 and HiPath 3350 (see Figure 3-1).
The CBCC central control board must be upgraded for HiPath 3000 V5.0. The "old"
>
CBCC board S30810-Q2935-A201 is not supported.
For Deutsche Telekom AG only: The CBCP board S30810-Q2935-B201 is not sup-
ported by HiPath 3000 V5.0 and must be replaced by a CBCC board S30810-
Q2935-A301.
Subboards
The following subboards can be used depending on the application:
Clock module
CMA
MMC
multimedia card
IMODN
integrated modem card new (optional)
LIM
LAN interface module (optional)
MPPI
music on hold (optional)
EVM
entry voice mail (optional)
Outputs, interfaces
Eight digital U
P0/E
For example, U
be connected here.
Four analog T/R subscriber lines
For U.S. only: These interfaces do not support the connection of external extensions via
OPS (Off-Premises Station) signaling.
3-18
or
CMS
(optional)
subscriber lines
workpoint clients or BS3/1 base stations for HiPath Cordless Office can
P0/E
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 5000