Switches and LEDs
Figure 3-8
CR8N (S30810-Q2513-X100)
LED statuses and their meanings
Table 3-22
CR8N - LED Statuses
Red LED
Green
LED
Off
Off
On
Off
Flashing
Off
On
On
Off
On
Off
Flashing Board operational.
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual
H1 (red)
LEDs
H2 (green)
Status
Board not receiving power or not plugged in
correctly.
Board is out of order.
Board is receiving power and board test is
in progress.
If the status does not change, the loadware
did not load correctly. Board is faulty.
Loadware is being loaded.
Board test unsuccessful, board is defective. Replace board.
Board test completed successfully. Board is
OK (temporary transition).
boards.fm
Boards for HiPath 3000
Central Boards
Action
Check plug contact on
board.
Wait
Replace board.