Customer Data Backup With Hipath Software Manager; Cdb Treatment When Replacing Central Hipath 3000 Hardware - Siemens HiPath 3000 Service Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

service.fm
Service
Service and Maintenance Tasks
12.2.1.2

Customer Data Backup with HiPath Software Manager

Definition
The HiPath Software Manager supports, among other things, the backup of customer databas-
es (Backup Manager) from all HiPath 3000/5000 systems in the same customer network (see
also Section 12.2.6, "Backing Up System Components (Backup Manager)").
The CDB backups are stored in a directory which must be defined in advance. The data backup
can either be started manually immediately or performed at a predefined time. A cyclic backup,
which saves the customer data at a set time every day, is also possible.
Refer to the help provided with the HiPath Software Manager for information on backing up cus-
tomer data with this tool.
12.2.1.3

CDB Treatment When Replacing Central HiPath 3000 Hardware

When replacing a central control board due to a hardware defect, for example, the following op-
tions are available for handling the CDB:
Procedure: After replacing the board, load the "current" CDB to the system
Step
1.
2.
3.
4.
5.
6.
7.
12-6
Copy the current CDB and save it on the MMC.
Disconnect the system from the power supply.
Remove the MMC.
Replace the central control board.
Insert the MMC.
Restart the system by plugging in the power plug.
The CDB previously stored on the MMC is loaded to the system RAM. The
customer system is now configured:
The CMI mobile telephones are logged on.
The V.24 baud rate is set up.
The ACD login port is configured.
All telephone options, such as volume and display, are determined per
station.
Activity
P31003-H3550-S403-4-7620, 02/05
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual