boards.fm
Boards for HiPath 3000
Peripheral Boards
TMCAS in HiPath 3750 and HiPath 3700
A maximum of four TMCAS boards can be used in the HiPath 3750 and HiPath 3700. For power
supply reasons, a maximum of two TMCAS are possible for one cabinet. Because the board
does not need a PCM highway, there are no restrictions concerning the 64 time-division multi-
plex channels per PCM segment. However, TMCAS must always be plugged in to the left of the
associated TMS2. An example of a TMCAS in the HiPath 3750 and HiPath 3700 cabinet is
shown in Figure 3-109.
X90
UPSM
TMS2-TMCAS connection cable:
C39195-A9700-B510, length = 0.2 m
Figure 3-109
TMCAS in HiPath 3750 and HiPath 3700 - Backplane View of the "8-Slot" Basic
Cabinet
Table 3-123
Assignment of the TMS2-TMCAS Connection Cable C39195-A9700-B510
SU connector Xx9, pin
6
26
2
22
33
35
4
Page 3-268 has information on the assignments for the two C39195-A9700-B512, -B514 TM-
CAS cables.
3-266
X80
X70
X60
X50
T
M
S
2
X88
X78
X68
X58
X89
X79
X69
X59
a-wire (T), receive
b-wire (R), receive
a-wire (T), transmit
b-wire (R), transmit
+5 V for board detection
+5 V (reserved)
GND
X40
X30
X20
X10
CBCPR
T
M
C
A
S
X48
X38
X28
X49
X39
X29
TMCAS cable:
C39195-A9700-B512/-
B514, length = 10 m
Function
HiPath 3000 V5.0, HiPath 5000 V5.0, Service Manual