Blower Motor Resistor - Suzuki sq-416-420-625 Service Manual

Table of Contents

Advertisement

BLOWER MOTOR RESISTOR

REMOVAL
1) Disconnect negative (–) cable (2) at battery (1).
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Open glove box (1), then remove screw (2).
4) Remove glove box.
5) Disconnect blower motor resistor (1) at coupler.
6) Remove heater blower resistor (1) by removing its fastening
screw (2).
INSPECTION
Measure each terminal-to-terminal resistance on resistor.
Resistance H-LO: Approx. 2.0 f
If measured resistance is incorrect, replace heater blower resistor.
1. LO
2. M1
3. M2
4. HI
INSTALLATION
1) Install heater blower resistor with screws.
2) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
H-M1: Approx. 1.0 f
H-M2: Approx. 0.4 f
HEATER AND VENTILATION 1A-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents