PSU Connector assignments (HiPath 1120)
Contacts
1
2 - 3
4 - 5
23 V
6 - 7
42 V
8 - 9
10
Table 3-33
PSU Connector assignments HiPath 1120
Warning
!
Turn the system power ON or OFF using the power supply cable or the input circuit
breaker.
3.7.2
HiPath1150/1190/1190R
Supply voltage: 110 - 230 Vac - 50/60 Hz, full range
●
The power supply's 5 x 20mm input (VAC) features two FAST fuses (250V - 4A)
●
NB
!
For the HiPath1150/1190/1190R with battery connection input (BBU), you need to
install the ferrite (C39022-Z7000-C7) in the AC power cable, which must be no fur-
ther than 20 mm from the female connector (see Chapter 3.12.7, "Power supply ca-
ble of the PSU - HiPath1150/1190/1190R" on page 3-123 ).
There are 2 types of power supply:
●
With battery connection socket
●
Without battery connection socket
●
Service Manual
Function
RSA
SPA
Free
Free
8 V
8 V
rms
rms
23 V
rms
rms
65 V
rms
rms
Free
Free
Free
Free
IM
Free
8 V
rms
23 V
rms
40 V
rms
Free
Free
Modules
Power Supply Unit (PSU)
3-95