Siemens SINUMERIK 840D Operator's Manual page 77

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

09.01
Typical errors
© Siemens AG, 2001. All rights reserved
SINUMERIK 840D/810D Configuring the OP 030 Operator Interface (FBO) – 09.01 Edition
The compilation is successful if the following message appears in
the output window:
"LINK: warning L4021: no stack segment
LINK: warning L4038: program has no starting address
copy proj.dat l:\bin\proj.dat
1 file(s) copied
MAKEFILE - 0 error(s), 2 warning(s)"
A proj.dat with the current date and time should now be located in
the L:\bin directory.
Test the system by reloading the OP 030 software in PC simulation
mode.- Switch to application configuration with the "Area Switchover
key" (F10 on the PC) and the "Continue" and "Config" softkeys.
The text "application text" should now appear twice in your PC
simulation.
Terminate execution of OP 030.
Error:
L:\bin\proj.dat does not have the current date.
Your modification has not taken effect.
Cause of the error:
The PC simulation may have been running when PROJ.DAT was being
recreated in the Visual Workbench. In this case, the simulation blocks
the file L:\bin\proj.dat, which cannot then be updated.
The Workbench output when linking PROJ.DAT then contains the error
message:
Illegal SHARE operation
0 files copied.
Remedy:
Exit the PC simulation and create PROJ.DAT again from the project
L:\proj\dat\makefile.
Development Kit (EU)
3 First Steps in Configuring
- L:\BIN\PROJ.DAT
EU/3-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810d

Table of Contents