PC simulation mode
Description
Requirements
Calling the OP 030
Exit
Typical errors in
PC simulation
mode
© Siemens AG, 2001. All rights reserved
SINUMERIK 840D/810D Configuring the OP 030 Operator Interface (FBO) – 09.01 Edition
In PC simulation mode, part of the data on the NC or PLC is emulated
by a simulation program. This mode is used exclusively to test the
layout of the user interface and the response of the menu control. The
contents of the data can differ greatly from the actual data in real use.
See also the previous section.
In file bt0.ini in \bin, change the entry
pc_test to pc_test = 1.
Caution! Please do not modify any other entries in this file or change
the order of the entries.
Change to the L:\bin directory.
The OP 030 software is started in PC simulation mode by entering
OP 030.
You exit the OP 030 software by entering the key combination:
<Ctrl>+<X>, then <Return>.
(Press and hold <Ctrl>, press <x>, then release both keys and press
<Return>)
bt0.ini missing; pc_test not set to 1.
proj.dat missing.
*.sp1,2 files missing.
sim.ovl missing.
bd, mpf, wks, spf + *.dir missing.
bd_tea.acc, bd_OP030.tea missing.