Set Protocols - HP P2000 G3 Cli Reference Manual

Msa system
Hide thumbs Also See for P2000 G3:
Table of Contents

Advertisement

set protocols

Description Enables or disables management services and protocols.
Syntax
set protocols
[debug enabled|disabled|on|off]
[ftp enabled|disabled|on|off]
[http enabled|disabled|on|off]
[https enabled|disabled|on|off]
[ses enabled|disabled|on|off]
[smis enabled|disabled|on|off]
[snmp enabled|disabled|on|off]
[ssh enabled|disabled|on|off]
[telnet enabled|disabled|on|off]
[usmis enabled|disabled|on|off]
Parameters debug enabled|disabled|on|off
Optional. Enables or disables debug capabilities, including Telnet debug ports and privileged
diagnostic user IDs. This is disabled by default. Enabling the service debug protocol allows remote
connection, through incoming ports only, by HP or HP's authorized representatives for
troubleshooting. Disabling the service debug protocol removes this access.
ftp enabled|disabled|on|off
Optional. Enables or disables the expert interface for updating firmware. This is enabled by default.
http enabled|disabled|on|off
Optional. Enables or disables the standard SMU web server. This is enabled by default.
https enabled|disabled|on|off
Optional. Enables or disables the secure SMU web server. This is enabled by default.
ses enabled|disabled|on|off
Optional. Enables or disables the in-band SCSI Enclosure Management Services interface. This is
enabled by default.
smis enabled|disabled|on|off
Optional. Enables or disables the secure Storage Management Initiative Specification interface
(SMI-S) interface. This option allows SMI-S clients to communicate with each controller's embedded
SMI-S provider via HTTPS port 5989. HTTPS port 5989 and HTTP port 5988 cannot be enabled at
the same time, so enabling this option will disable port 5988. This is enabled by default.
snmp enabled|disabled|on|off
Optional. Enables or disables the Simple Network Management Protocol interface. Disabling this
option disables all SNMP requests to the MIB and disables SNMP traps. To configure SNMP traps
use the
set snmp-parameters
ssh enabled|disabled|on|off
Optional. Enables or disables the secure shell CLI. This is enabled by default.
telnet enabled|disabled|on|off
Optional. Enables or disables the standard CLI. This is enabled by default.
usmis enabled|disabled|on|off
Optional. Enables or disables the unsecure Storage Management Initiative Specification (SMI-S)
interface. This option allows SMI-S clients to communicate with each controller's embedded SMI-S
provider via HTTP port 5988. HTTP port 5988 and HTTPS port 5989 cannot be enabled at the same
time, so enabling this option will disable port 5989. This is disabled by default.
Example Disable unsecure HTTP connections and enable FTP:
# set protocols http disabled ftp enabled
Success: Command completed successfully. (2012-01-21 14:46:55)
See also
• show protocols
command. This is enabled by default.
HP P2000 G3 MSA System CLI Reference Guide 169