Set Enclosure - HP P2000 G3 Cli Reference Manual

Msa system
Hide thumbs Also See for P2000 G3:
Table of Contents

Advertisement

set enclosure

Description Sets an enclosure's name, location, rack number, and rack position. Set these parameters to values
that help you identify and locate the enclosure. A value that contains a space must be enclosed in
double quotes.
These values are used when user interfaces show enclosure-related data; for example, in output of
the
show enclosures
Syntax
set enclosure
[name new-name]
[location location]
[rack-number rack-number]
[rack-position rack-position]
enclosure-number
Parameters name new-name
A new name for the enclosure. The name can include a maximum of 20 bytes, using printable UTF-8
characters except double quote, left angle bracket, comma, or backslash. A value that contains a
space must be enclosed in double quotes.
location location
The location of the enclosure. The name can include a maximum of 20 bytes, using characters
except double quote, left angle bracket, comma, or backslash. A value that contains a space must
be enclosed in double quotes.
rack-number rack-number
The number of the rack containing the enclosure, from 0–255.
rack-position rack-position
The enclosure's position in the rack, from 0–255.
enclosure-number
The enclosure ID.
Example Set parameters for enclosure 1:
# set enclosure 1 name Storage-5 location Lab rack-number 9 rack-position 3
Success: Command completed successfully. (2012-01-21 12:03:12)
See also
• show enclosures
150 Alphabetical list of commands
command and in event-log entries related to enclosures.