GE NX-10 Installation Manual page 70

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

Is used to select the amount of time an output will remain activated when an output triggers. If this
location is programmed as a zero, the output will follow the particular event.
LOCATION 5 - PROGRAMMING SPECIAL FUNCTIONS AND PARTITIONS FOR OUTPUT C (2
segments, feature selection data)
Segment 1 - selects the following special conditions
Option
Function
1
ON
If output should time in minutes
OFF
If output times in seconds
2
ON
Output "Latch": should latch until a code is entered
OFF
Output is timed
3
ON
Timed or output should be reset if a code is entered while it is being timed
OFF
Stays timed (not reset) after code is entered
4
ON
For inverted output
5
ON
Disables output during listen-in (only events 12-16)
6
Reserved
7
Reserved
8
Reserved
Segment 2 - selects the following partitions
Option
Function
1
ON
If the event should activate when it occurs in partition 1
2
ON
If the event should activate when it occurs in partition 2
3
ON
If the event should activate when it occurs in partition 3
4
ON
If the event should activate when it occurs in partition 4
LOCATIONS 6 & 7 - RESERVED
LOCATION 8 - AUTHORIZING USERS 1 - 10 TO TRIGGER OUTPUTS A-C (10 segments, feature
selection data)
When activating outputs with a user code (event 30), location 8 can be used to restrict certain codes
from activating certain outputs. Location 8 contains 10 segments. Segment 1 corresponds to user 1,
segment 10 corresponds to user 10.