UNIVERGE SV8100
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
20-06-01
Class of Service for Extensions
20-08-01
Class of Service Options
(Outgoing Call Service) –
Intercom Calls
21-01-09
System Options for Outgoing
Calls – Ringdown Extension
Timer (Hotline Start)
21-11-01
Extension Ringdown (Hotline)
Assignment
SV8100 Features and Specifications Manual
Description/Comments
Assign a Class of Service (1~15)
to an extension.
Turns Off or On Intercom calling
for the extension.
After the user lifts the handset, the
extension automatically calls the
ringdown destination after this
interval (0~64800 seconds). A
setting of 0 immediately rings the
programmed extension. Any other
setting delays the ringdown the
number of seconds programmed.
Program the ringdown (Hotline)
source and destination (target)
number, up to 24 digits (512
Hotline assignments). Remember
to include the trunk access code
(usually 0) in front of the number
when dialing outside numbers.
When programming Speed Dial –
System numbers as the
destination, the entry should be
753 + bin number (the service
code for Speed Dialing and the
Speed Dial bin number).
Assigned Data
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
0 = Off
1 = On
(default = 1 for
COS 1~15)
0~64800 seconds
(default = 0 seconds)
#
0, ,
, Pause, Hook
Flash,
@ (Code to wait for
answer supervision)
(maximum 24 digits)
(default not assigned)
Issue 1.0
Level
1
2
3
2 - 895