1.13 P

1.13.7 Power Failure Transfer

Description
If the power supply to the PBX fails, specific single line telephones (SLTs) are automatically connected to
specific CO line (Power Failure Connections). The PBX will switch from the current connections to the
Power Failure Connections, and all existing conversations will be disconnected.
Only CO line conversations handled by Power Failure Connections can be made during a power failure.
Conditions
Only CO line calls can be made during a power failure. All other features do not work.
Only ports 1 and 2 of the pre-installed LCOT card and ports 1 and 2 of the pre-installed hybrid ports
can be used for Power Failure Connections.
Note
The Power Failure Connections between the LCOT card and hybrid ports are automatically kept
so that the conversation is maintained when the power is restored and the Main Board is
recovering.
Installation Manual References
2.10.1 Power Failure Connections
Programming References
PC Programming Manual
None
PT Programming Manual
None

1.13.8 Predialing

Description
A display proprietary telephone (PT) user can check and correct the number to be dialed on-hook. The call
will be initiated after going off-hook.
Conditions
Storing the Predialed Number in Personal Speed Dialing
The predialed number can be stored in Personal Speed Dialing by pressing the AUTO DIAL/STORE
button. (→ 1.16.3 Speed Dialing, Personal) In this case, the extension will enter personal programming
mode automatically so that a name can be assigned to the stored number.