Incoming Call Trunk Setup - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
UNIVERGE SV8100
Level:
IN
Description
Use Program 22-02 : Incoming Call Trunk Setup to assign the incoming trunk type
for each trunk. There is one item for each Night Service Mode.
Input Data
Item
No.
01
Conditions
Programming Manual
Program 22 : Incoming Call Setup
Trunk Port Number
Day/Night
Incoming Type
Mode
1~8
0
= Normal
1
= VRS (second
dial tone if no
VRS installed)
2
= DISA
3
= DID
4
= DIL
5
= E&M Tie line
6
= Delayed VRS
7
= ANI/DNIS
8
= DID(DDI) Mode
Switching
When connecting to T1 trunks, after changing Program 22-02-01 to match the
Telco connected T1 service type, the T1 cable or the T1 blade must be unplugged
and then reconnected in order for the T1 blade to sync.
When the trunk type is set to 3 (DID), the DID Transfer to Destination in 22-11-04
for each DID feature is not supported. This feature is supported only for DID
trunks when assigned as VRS.
When the trunk type is set to 3 (DID), the DID Intercept Destination feature for
each DID is not supported. This feature is supported only for DID trunks assigned
as VRS.

22-02 : Incoming Call Trunk Setup

Default
0
Use this option to set the
feature type for the trunk
you are programming.
Issue 1.0
001~200
Related
Description
Program
14-04
2 - 289