Table 5-3 Caller Id Switch (Sw10-17) Settings Of Ltrk/8 Card; Figure 5-3 Caller Id Card Installation - Panasonic DBS 576 Technical Manual

Section 300 installation
Hide thumbs Also See for DBS 576:
Table of Contents

Advertisement

Section 300-Installation
Figure 5-3. Caller ID Card Installation:
2. For every CID circuit to be used, set the DIP switch to OFF (CID). Otherwise set
Table 5-3. Caller ID switch (SW10-17) settings of LTRK/8 card
Switch
Setting
SW10
ON
OFF
SW11
ON
OFF
SW12
ON
OFF
SW13
ON
OFF
SW14
ON
OFF
SW15
ON
OFF
SW16
ON
OFF
SW17
ON
OFF
576-13-300
the switch to ON (LS).
Description
Circuit 1 is in loop start mode and does not receive caller ID information.
Circuit 1 is set to receive Caller ID information (requires CID card).
Circuit 2 is in loop start mode and does not receive caller ID information.
Circuit 2 is set to receive Caller ID information (requires CID card).
Circuit 3 is in loop start mode and does not receive caller ID information.
Circuit 3 is set to receive Caller ID information (requires CID card).
Circuit 4 is in loop start mode and does not receive caller ID information.
Circuit 4 is set to receive Caller ID information (requires CID card).
Circuit 5 is in loop start mode and does not receive caller ID information.
Circuit 5 is set to receive Caller ID information (requires CID card).
Circuit 6 is in loop start mode and does not receive caller ID information.
Circuit 6 is set to receive Caller ID information (requires CID card).
Circuit 7 is in loop start mode and does not receive caller ID information.
Circuit 7 is set to receive Caller ID information (requires CID card).
Circuit 8 is in loop start mode and does not receive caller ID information.
Circuit 8 is set to receive Caller ID information (requires CID card).
DBS 576 (USA), issued 6/2/98
Chapter 5 - Trunks and Extensions
5-7