Table 5-16 Switch Setting For Sw1 On Pri/23 Card; Figure 5-10 Connection Of T-Point Isdn Primary Rate Interface (Pr1) - Panasonic DBS 576 Technical Manual

Section 300 installation
Hide thumbs Also See for DBS 576:
Table of Contents

Advertisement

Chapter 5 - Trunks and Extensions
Table 5-16. Switch Setting for SW1 on PRI/23 Card
Switch No.
6. Insert the PRI/23 card into the specified flexible slot (see page 4-36)
7. Connect the 8-conductor modular jack via the CSU to the T-point ISDN primary
8. Pass the T-point ISDN rate carrier wires with 8-conductor modular jack through
Figure 5-10. Connection of T-Point ISDN Primary Rate Interface (PR1)
5-24
Distance from the DBS 576 to the CSU
0 to 150 ft.
SW1-1
ON
SW1-2
OFF
SW1-3
OFF
SW1-4
OFF
SW1-5
OFF
SW1-6
OFF
SW1-7
OFF
SW1-8
rate carrier line.
the wiring aperture of the cabinet and connect it to the modular connector on the
PRI/23 card.
DBS 576 (USA), issued 6/2/98
Section 300-Installation
150 to 450 ft.
450 to 655 ft.
OFF
ON
OFF
ON
OFF
ON
OFF
Not used
OFF
OFF
ON
OFF
ON
OFF
ON
576-13-300