4. Repeat Steps 1 through 3 for each Remote radio to be installed in the
network.
This concludes the basic setup of a Remote radio. A full listing of
Remote programming commands is given in
RADIO MANAGEMENT, beginning on Page
With all radios connected, you are ready to connect data devices to the
transceivers so that their operation can be tested over the wireless
network. This is discussed in the next step.
STEP 5—CONNECT TERMINAL EQUIPMENT
This step describes connection of external data equipment to the Remote
radio. Verify that your transceiver is capable of supporting your devices.
See
Table 1-1 on Page 6
Be sure not to overload the radio network with high-bandwidth LAN
traffic during this test. Refer to the
Page 51 for more information.
Ethernet Device Connection to Remote
NOTE: Verify that the Remote
command. If it is not, use the
port.
Connect an Ethernet endpoint to the Remote
supports any Ethernet-compatible device. This includes a device that
uses Internet Protocol (IP).

Serial Device Connection to Remote

Connect a serial device to the Remote
settings are compatible with the connected device (baud rate, data
format, and so on).
STEP 6—CHECK FOR NORMAL OPERATION
With data equipment connected, you are ready to check the transceivers
for normal operation.
Observe the transceiver LEDs on the top cover for the proper
indications. In a normally operating system, the following LED
indications should be seen within 30 sec of start-up:
Lit continuously
PWR—
—Lit continuously (unless Sleep is enabled)
LINK
—On, or blinks intermittently
ETH
—Blinks to indicate data communications
COM1/COM2
MDS entraNET Technical Manual
CHAPTER 4 REMOTE
99.
for a summary of model capabilities.
Bridge Configuration Menu
port is enabled (on) using the
ETH
ETH=ON
ETH
port and verify that the port
COM2
on
ETH
command to enable the
port. The
port
ETH
25