Chapter 2 Basic Operation
2.1 Powering On and Off
2
2.1.4

Powering Off

This section explains how to turn off the ETERNUS DX Disk storage system.
There are two ways to turn the power off:
Via the Power switch
Press the Power switch to turn off the ETERNUS DX Disk storage system.
Via ETERNUS Web GUI or ETERNUS CLI
Use ETERNUS Web GUI or ETERNUS CLI to turn off the ETERNUS DX Disk storage
system.
IMPORTANT
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
After about two minutes, check that the READY LED of the controller enclosure
is lit up.
LINE
FAULT
POWER
POWER
READY
FAULT
MAINT/ID
CACHE
When turning off the ETERNUS DX Disk storage system, the power
shuts off after the data in the cache memory is written to the drives.
Therefore, it may take one minute (maximum six minutes) for the power
supply to be completely turned off.
Do not turn off the power of the ETERNUS DX Disk storage system, the
network devices that connect the ETERNUS DX Disk storage system
and the server while the server is operating, as this may result in the
loss of data or prevent data from being saved.