Configuring Alert Settings; Defining Snmp Alerts - HP StorageWorks 8000 - NAS User Manual

Nas 8000 user's guide
Hide thumbs Also See for StorageWorks 8000 - NAS:
Table of Contents

Advertisement

Configuring Alert Settings

Defining SNMP Alerts

If you are using a network management product such as HP OpenView, CA
Unicenter, or Tivoli Network Node Manager, you can define the names of
management workstations to receive notification in case of a failure. For more
information about these products, see the Installation and User's Guide for the HP
Enterprise management smart plug-ins, which can be accessed at
http://www.hp.com/support/emsp.
Note:
functionality of the device. In the event of a hardware failure or system alert, messages
are sent through SMTP (email), or they are logged in the system log.
To define the management servers to notify:
1. In Command View NAS, click the Configuration tab.
2. Under Alerts/Logging, select SNMP Alerts.
3. Select Actions > Edit SNMP Settings.
4. Enter the SNMP password required for network management tools to retrieve
5. Enter the name or IP address of the server you want the system to notify in the
6. Click OK.
To edit or delete the Trap Destinations, click Actions > Edit SNMP Settings,
then:
Click OK to apply each change.
See
server.
The information on this screen is optional. Blank fields do not affect the
operational or configuration information from the device in the Community
String field.
SNMP Trap Destinations field.
Click the incorrect entry to modify it.
Click the entry and click the delete icon to remove it.
SNMP Trap Definitions
on page 225 for a list of the traps sent by the NAS
Configuring Your System and Network
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 8000

Table of Contents