Focus - Canon RE-350 Control Interface Commands Manual

Video visualizer
Hide thumbs Also See for RE-350:
Table of Contents

Advertisement

Focus Far: Step
• Function:
Moves the focus lens in the far direction one step. This operation stops automatically.
• Timing of the "C-response Packet" sent to the PC:
Right after the focus lens stops
• The parameter of the "C-response Packet":
$0000 fixed
• The maximum operation time (msec):
2000 millisecond
• Command format:
Header
ID number
$10
$ 8 *
Focus: Stop
• Function:
Stops the focusing motor that moves the focus lens.
• Timing of the "C-response Packet" sent to the PC:
Right after the focus lens stops.
• The parameter of the "C-response Packet":
$0000 fixed
• The maximum operation time (msec):
500 millisecond
• Command format:
Header
ID number
$10
Command
$ 1 3
Command
$ 8 *
$1 4
Parameter MSH
Parameter LSH
$ 0 3
$ 0 0
Parameter MSH
Parameter LSH
$ 0 0
$ 0 0
32