Interface Specifications - Sanyo MPX-CD163 Instruction Manual

Sanyo mpx-cd163 multiplexer: instruction manual
Table of Contents

Advertisement

Available languages

Available languages

INTERFACE SPECIFICATIONS

RS-232C
9-pin connector specifications
Communication is carried out in units of 1 byte. After the computer transmits one byte of data, it waits for a
response from the multiplexer, and then transmits the next byte of data.
To start sending commands, an ON (F6) command is sent. The multiplexer will continue to receive
commands until an OFF (F7) command is sent to stop. The multiplexer sends an ACK (OA) each time it
receives a command.
See Table 4 - Command Table on page 79.
RS-485
RJ-11 connector specifications
A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. It is recommended that a special
controller be used. Contact the place of purchase for further details on obtaining a special controller.
English
Pin No.
1
1
2
3
4
5
2
3
4
6
7
8
9
5
6
7
8
9
Data format
Mode
Asynchronous
Character length
8 bits
Data transmit speed
2400, 4800, 9600, 19200 bps
Parity
None
Stop bit
1
Communication protocol
Pin No.
1 2 3 4 5 6
1
2
3
4
5
6
Data format
Mode
Asynchronous
Character length
8 bits
Data transmit speed
2400, 4800, 9600, 19200 bps
Parity
None
Stop bit
1
Communication protocol
Signal
RXD
TXD
GND
RTS
Request to send
Pin A signals
Pin B signals
Spare
Spare
Spare
Spare
Signal B
Signal A
Signal A
Signal B
Spare
Spare
Spare
Spare
– 75 –
Operation
Signal direction
Receive data
Computer
Transmit data
Multiplexer
Ground
Multiplexer
Multiplexer
Computer
Computer

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpx-cd93

Table of Contents