Page 1
MPX-MS10P INSTRUCTION MANUAL English Multiplexer Deutsch Multiplexer Français Multiplexeur Italiano Multi distributore About this manual Über diese Bedienungsanleitung • Lesen Sie bitte vor der Montage und dem Inbetriebnehmen der • Before installing and using the camera, please read this manual Kamera zuerst diese Bedienungsanleitung sorgfältig durch und...
Page 2
Refer servicing to qualified personnel only. If the power supply cord (AC power cord) of this appliance is damaged, it must be replaced. Return to a SANYO Authorised Service Centre for replacement of the cord. Location IMPORTANT NOTE (U. K. Only)
CONTENTS FEATURES • FEATURES ..............2 Up to 10 images multiple field recording Multiple field recording of the images from up to 10 ACCESSORIES .............2 cameras using only one VCR, allowing for a compact LOCATION OF CONTROLS AND INDICATORS and cost effective simple system. Front Panel..............3 •...
LOCATION OF CONTROLS AND INDICATORS Front Panel 5 6 7 8 9 F Power ON switch and indicator SEQUENCE select button and indicator STAND BY indicator MULTI (Screen splitting) button and indicator This indicator will come on when the power cord is LIVE camera signal select button and indicator connected in a live power outlet.
LOCATION OF CONTROLS AND INDICATORS Back Panel (Control terminal) Camera IN (Camera input) terminal Camera OUT (Camera output) terminal VCR IN (Video cassette recorder input) terminal VCR OUT (Video cassette recorder output) terminal MONITOR OUT (Monitor output) terminal Signal Signal AL OUT (Alarm output) terminal Alarm input 1 14 No operation...
Make sure all the connections are correct, if not that may cause a fire and/or damages. • With model MPX-MS10P, use black and white cameras only. If colour cameras are used, that may cause image beat, etc. Monitor (sold separately)
CONNECTIONS Assembling the D-sub 25-pin plug Preparing the cable Installing the covers Insert the cable in the cover nut (A), then Insert plug plate (C) in the cover (B) slot. Check remove the cable sleeve as shown. that the shielding tape is within about 2 – 3 mm from the end of the cover (B).
BASIC FUNCTIONS Using this unit you can monitor in split screen or full screen mode, according to the received camera input mode, the image from all the cameras connected. Also, the image from the cameras can be recorded using a VCR, then played back by switching to VCR playback mode.
BASIC FUNCTIONS Resetting the Menus Button Lock Function The date, the time, the title indicating the monitoring This unit is equipped with a function that lets you lock location or alarms, etc. are entered using on-screen the buttons to prevent any undesired operation during menus, and if the unit is moved or the installation setup camera live mode or VCR playback mode.
WHEN USING THE UNIT AS A FRAME SWITCHER Camera Live Picture Mode (Full screen surveillance) To use the unit as a frame switcher, in the “4. DISPLAY SET OTHER” menu set “MULTI MODE” to “OFF”. (For detailed instructions, please refer to page 7.) When the unit is first turned on, it will be in camera live viewing mode.
WHEN USING THE UNIT AS A FRAME SWITCHER VCR Playback Mode While viewing live camera pictures, start playback on the VCR, then press the VCR button to view the VCR playback image on the monitor. If a camera picture is not recorded on the tape, the message “NO VIDEO” will be displayed.
WHEN USING THE UNIT AS A FRAME SWITCHER Split Screen Viewing Every time the MULTI button is pressed, one of the 5 split screen combinations is selected. The camera indicators corresponding to the cameras displayed on-screen will light. NOTES: • The unit will remember the last selected screen display combination, and when turned on again it will select it automatically.
WHEN USING THE UNIT AS A FRAME SWITCHER x2 Zoomed In Image Viewing Example: To watch the image from camera 8 at x2 zoom. Press the ZOOM button, then press the camera SELECT (8) button. The image will be zoomed in (X2), and “Z” will flash instead of the camera number (8). (The ZOOM indicator and the camera (8) indicator will flash.) To cancel the zoom mode, press the ZOOM button one more time.
WHEN USING THE UNIT AS A FRAME SWITCHER 4 Divisions Split Screen Sequential Viewing From the split screen display, press the SEQUENCE button and 4 images at a time will be displayed in a 4 divisions split screen, switching sequentially. NO VIDEO NO VIDEO Alarm Operation During VCR Playback...
WHEN USING THE UNIT AS A MULTIVIEWER Camera Live Picture Mode (Split screen surveillance) To use the unit as a multiviewer, in the “4. DISPLAY SET OTHER” menu set “MULTI MODE” to “ON”. (For detailed instructions, please refer to page 7.) When the unit is first turned on, it will be in camera live viewing mode.
WHEN USING THE UNIT AS A MULTIVIEWER Alarm Display During Camera Live Picture Viewing When an input such as a door bell, an interphone, etc. connected to the CONTROL terminal on the unit rear panel of the unit sends an alarm trigger, the display will automatically switch to 10 divisions split screen display.
ON-SCREEN MENUS To display the main menu, or return to the main menu from a sub-menu, press the MENU button. To select the different sub-menus, and enter the settings use the m, –, +, O, or « buttons. When a menu is displayed, the indicators corresponding to the buttons that can be used with that particular menu will light.
CLOCK SETUP Menu 1 Example: To set the clock to October 15, 1997 at 15:20 PM. Press the MENU button, make sure “1. CLOCK SET” is selected, then press the MENU button again. Press the + (or –) button to set the day (15), then press the «...
TITLE SETUP Menu 2 Example: To set the title “GATE – – 5F” for the camera 5. Press the MENU button, then press the O button to select “2. TITLE SET”, then press the MENU button again. Press the MENU button, then press the O button to select “5”...
ALARM SETUP Menu 3 Press the MENU button, then press the O button to select “3. ALARM SET” and press the MENU button again. With the “ON” setting selected for “BUZZER”, press the O button. Press the + (or –) button to select the desired setting for “DURATION”, then press the O button.
CLOCK, TITLE DISPLAY Menu 4 Press the MENU button, then press the O button to select “4. DISPLAY SET” and press the MENU button again. Press the + (or –) button to select “ON” for “LIVE CLOCK”, then press the m button. Press the O button to set the clock display position, then press the m button.
VCR SETUP Menu 5 Set the recording mode according to the type of VCR used. Press the MENU button, then press the O button to select “5. VCR SET” and press the MENU button again. Press the + (or –) button to set the “VCR MODE”, then press the O button.
Page 23
VCR SETUP • VCR ALARM REC SPEED Under normal conditions, set “VCR REC SPEED” to “3H”. • If “VCR ALARM REC SPEED” is set to “3H” (or “6H” for LP Enter the setting corresponding to the connected VCR mode), change the setting to “F3H” (or “F6H” for LP mode). alarm recording speed.
ALARM DATA DISPLAY Menu 6 The ALARM DATA display will indicate the alarm trigger input camera number, date and time. The data for the last 100 alarm triggers can be displayed. Press the MENU button, then press the O button to select “6.
SPECIFICATIONS Video signal format : Based on PAL B/W signal standard Camera signal input synchronisation : Asynchronous : VS or VBS, 1.0Vp-p/75 Ω/HI (auto switching), BNC connector x 10 Camera input terminals (IN) Camera output terminals (OUT) : Through output of each input, BNC connector x 10 : Composite input, VS/VBS, 1.0Vp-p/75 Ω, BNC connector x 1 VCR input terminal (VCR IN) : Composite output, VS/VBS, 1.0Vp-p/75 Ω, BNC connector x 1...
Page 26
SANYO Electric Co., Ltd. 1AC6P1P1487-- L8FF5/XE (A) (1197KP-NI01) Printed in Japan...