MELSEC-A
CPU Model
Microcomputer Program
Microcomputer Program
Capacity
Addresses
I
AOJ2HCPU
A2CCPU
I
Max.
l4K
bytes
I
WOOHto37FEH
I
AlCPU
AINCPU
I
Max.
10K
bytes
1
WOOHto27FEH
I
A2CPU(S1)
AZNCPU(S1)
I
Max.
26K
bytes
I
WOOH to 67FEH
I
2) Addresses are set by converting 4-digit hexadecimals into ASCII.
3)
A character area error 06H occurs if the following condition is
not met:
Head address
+
(number of bytes)
-
1
2
microcomputer pro-
gram capacity.
A3CPU
A3NCPU
A3HCPU
A3MCPU
A73CPU
Main and sub
Max.
58K
bytes
WOOH to E7FEH