A Specifications
A.2 Environmental Specifications
Table A.1: Technical Specifications
(Continued)
Property
Mounting orientation
A.2

Environmental Specifications

Table A.2: Environmental Specifications
Property
Insulation specifications
Over voltage category
Pollution degree
Protection (EN 60529)
Ambient Operating temperature
(EN/IEC 60068-2-1/2/14)
Ambient Storage and transportation
temperature
(EN/IEC 60068-2-1/2/14)
Relative humidity
(EN/IEC 60068-2-78)
Vibration sinusoidal operating
(EN/IEC 60068-2-6)
Shock operating
(IEC 60068-2-27)
8VZZ005286 B
Relay contacts: Not specified
Any, provided that the cable entry (or quick-release connector) is facing down
Characteristic/Value/Standard/Regulation
IEC 60664-1
II
2
IP66/IP67 (all versions)
-40° to 70°C (-40° to 158°F)
Below -20°C, the LCD may be blank, but all other work
OK including the safety relay function.
-20° to 70°C (-4° to 158 °F) with quick connector Ex models "QC"
Must not be installed in direct sunlight.
-40°C/85°C (-40°F/185°F)
5 - 95% non-condensing
Frequency range: 5 - 200 Hz
Acceleration: 20m/s
Displacement: 0.15 mm peak
Acceleration: 15G
Duration of pulses: 11 ms duration (half sine wave)
Three shocks in each direction (six pulses in each axis)
Value
2
peak (2 G)
133