CO NF IG UR AT IO N
6.13

Passwords

There are administrator password and monitor password. The administrator can make
changes to the configuration, whereas a monitor can only view information.
To change or set passwords, click Configuration > Username/Passwords in the left naviga-
tion column. Passwords must be 10 characters long.
6.14

Store and Retrieve Settings

The Configuration > Store Retrieve Settings screen provides the following options:
– Factory Default – it can load the factory default parameters. To do so, select Set Factory
Defaults.
– Upload Configuration to device – it can upload the configuration to the gateway from a
previously saved file. User must "Choose" the Config file, add "Passphrase", and click
"Send Configuration to Device".
– Send Configuration to File – it can export gateway's existing configuration to a PC's hard
drive. A "Passphrase" is required.
– Export As-Built Configuration - it can export gateway's existing configuration in text for-
mat. It will only export configuration of connected devices.
A 10-character passphrase is required to protect/validate the file before it can be
saved or retrieved from a PC. It prevents unauthorized users from applying the sys-
tem configuration file to an unauthorized access point to gain access to the net-
work. Always record this passphrase when saving a configuration file. It will need
to be re-entered each time that specific configuration file is uploaded to the AWIN
GW100 rev.2.
3B NP 10299 2 B

Figure 21: Configuration - Username/Password Modification screen

In this case, IP address is not restored to factory default. It remains as-is. How-
ever, if you want to also reset IP address, you can use hard reset option.
PA SS WOR DS
45